Press the left button, drag the mouse, rotate the cube, see more information

Limit Discounts

Through this webpage, choose online customer service communication, or message board. Leave your needs and get limited time discounts, up to 10% off, saving you a fortune. This discount has an indefinite period, and places are limited on a first-come, first-served basis.

Payment Method

We support various payment methods:
T/T payment
VISA
paypal
MasterCard
Alipay etc
Save time in your buying process.

Certified Product

The company's products have passed multiple national
certifications:
for example:
United States: ASME
EU: CE
Eastern Europe: EAC
Russia: GOST
Singapore: MOMO
etc
Buy products, buy with confidence, use with confidence

Product Type

Domestic hot water and heating series: gas hot water boiler, vacuum hot water boiler, vertical atmospheric pressure hot water boiler, electric hot water boiler Factory use, high temperature steam: wns fuel gas steam boiler, szs water tube steam boiler, vertical steam boiler, electric steam boiler

About Us

FANGKUAI is founded in 1998, which is a clean fuel boiler enterprise integrating R&D, manufacturing, sales and service. In the past 20 years of development and innovation, the company has grown into a global enterprise, and its products have been exported to more than 80 countries including Russia, Mongolia and Thailand, and have established long-lasting cooperative relations with local enterprises!

Contact Us

If you are interested in our company or products, you can contact with us through online consulting, demand table submission, e-mails and telephones. Our staff shall wholeheartedly provide product information, application knowledge and good service for you.

I have a Burnham boiler with a honeywell s8610m continuous

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :I have a Burnham boiler with a honeywell s8610m continuous
  • Supply Capacity : 10 units/month :I have a Burnham boiler with a honeywell s8610m continuous
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

boilermanufactory

Get display discount

boiler
Contact us

Global Sales Hotline:
0086-371-60922096

Email: [email protected]

Voicemail
  • Honeywell S8610U Ignition Module — Heating Help: The Wall

    Checked and found the problem to be a broken wire to the connector for the vent/damper on the Honeywell S8610M ignition module. When pushing against the vent/damper connector on the module the boiler would fire. I replaced the Honeywell S8610M ignition module with the new S8610U module attaching lead to lead in the same sequence.Get Price

  • Honeywell S86310U — Heating Help: The Wall

    This control is an S8610U ( a Universal Application Ignition Module) and needs to be wired differently than the original S8610M control. The original S8610M did not have a Terminal 7 or TH terminal. The vent damper on this boiler is not plugged into the ignition module. It is probably plugged into the polarized sub harness.Get Price

  • S8610U Universal Intermittent Pilot Module - Honeywell

    modules manufactured by Honeywell, Robertshaw, Penn-Johnson and others. The S8610U module provides ignition sequence, flame monitoring, and safety shutoff for intermittent pilot central furnaces, residential boilers, and other heating appliances. The S8610U replaces existing flame rectification type intermittent pilot ignitionGet Price

  • Burnham Boiler L4080D1234 100189-01 High Limit Aquastat

    Burnham Boiler High Limit Aquastat 140-240F P205 L4080D1234 100189-01. This is a brand new Original Equipment Manufacturer (OEM) Burnham Boiler high limit aquastat 140-240F, part# 100189-01. Replaces the following part #'s: 100189-01, L4080D1234 This part is used in, but not limited to the following models: (On your keyboard, Press Ctrl + F to find model number below)Get Price

  • Burnham Burnham-Series-5B-Boiler-Installation-Operating

    : Burnham Burnham-Series-5B-Boiler-Installation-Operating-Instructions-738082 burnham-series-5b-boiler-installation-operating-instructions-738082 burnham pdf . Open the PDF directly: View PDF . Page Count: 112 [warning: Documents this large …Get Price

  • Burnham continuous ignition problem :Buzzing Noise

    Nov 17, 2012 · I have 3 honeywellzone valves & honeywell electronic thermostats. System was installed by lic plumber, who has been trying to resolve over 6 follow up visits to date & claims to have contacted burnham engineering. Boiler circ kicks on, auto damper opens ign sounds (slight buzzing noise) &burner ignites.Get Price

  • SERIES 5B ATMOSPHERIC - Burnham Commercial Boilers

    Aug 05, 2019 · 2.5 Boiler shall have individual clean out openings between sections covered with insulated steel flue cover . plates on front and rear of boiler. 2.6 Boiler flue canopy(s) shall be constructed of heavy gauge aluminized steel. 2.7 A horizontal to vertical drafthood(s) shall be furnished for each boiler.Get Price

  • Replacement for Honeywell Furnace Integrated Pilot Module

    The igniter on my Burnham boiler failed, and I ordered this one to replace. The local cost was literally 3 times more at the time that I ordered it, and it seemed easy enough to install that I didn't call a heating/cooling service company to do the work. This unit is a later Honeywell design than the one it replaced, but the terminals are well Get Price

  • V11 SERIES PRESSURE FIRED - Burnham Commercial Boilers

    It shall have fixed reset ratio of 1.5:1, 1:1, or 1:1.5. It shall consist of a T475A control with 30ft. capillary on first boiler and (1) T6031A outdoor air sensor with 20 ft. capillary and bulb shield on each additional boiler. Provide a Burnham Control Package B.Get Price

  • Boiler upgrade? — Heating Help: The Wall

    The boiler was installed in 1992 and has been well-maintained, but is in need of a gas control valve repair. I also have an electric water heater that just went out. I'm faced with either repairing the Burnham and upgrading to a gas water heater, or replacing the entire system with a high efficiency mod-con unit combined with DHW.Get Price

  • Heating boiler aquastat control diagnosis, troubleshooting

    Honeywell L4026B Aquastat control instructions (contact Honeywell Corporation) Here is some basic description of the Honeywell L4026B control, also available at .honeywell.com L7224U1002- is a universal electronic aquastat (replacing over 40 other aquastat models) that provides circulator, burner and boiler temperature control with Get Price

  • Boiler Plus - Honeywell Home Heating Controls

    The following Honeywell heating controls are Boiler Plus compliant when used with a combi boiler, qualifying either under the Load Compensation section or as a 'Smart Thermostat'. T3 and T4 Series Programmable Thermostats. Load compensation with either 'fuzzy logic' protocols or OpenTherm (T4R & T4M only)Get Price

  • BURNHAM BOILER MANUALS PDF, NTI TRINITY

    Dec 16, 2021 · BURNHAM BOILER MANUALS PDF, NTI TRINITY. Nti trinity. Manual hot oil boiler. S8610m honeywell. Customer service representatives. Best boiler homes. DOCUMENT SEARCHER. SONY KV HA14P52 TRINITRON COLOR TV SERVICE MANUAL, VW PREMIUM BLUETOOTH USER MANUAL, CITROEN C6 MANUAL. SEARCH BURNHAM BOILER MANUALS …Get Price

  • BURNHAM 5B SERIES INSTALLATION AND OPERATION MANUAL …

    Page 1 3050579 Commercial Boilers .burnhamcommercial.com 8141302R15 - 12/12 PRice - $5.00; Page 2 SecTiON i – eQUiPMeNT cHecK LiST U.S.A. EQUIPMENT CHECK LIST (For Canadian Equipment Check List, Turn to Pages 4 and 5) This Equipment Check List has been provided so that the Installer can determine if all parts have been provided for the boiler ordered.Get Price

  • 69-1955 03 - Honeywell Customer Portal

    residential boilers, and other heating appliances. The S8610U replaces existing flame rectification type, intermittent pilot ignition modules with the following characteristics: • Single rod (local sense) or two rod (remote sense) flame sensing • Non-100 percent shutoff, 100 percent shutoff/lockout, or 100 percent shutoff/continuous retryGet Price

  • Honeywell S8610M Continous Retry Crown Boiler Circuit

    Share - Honeywell S8610M Continous Retry Crown Boiler Circuit Board. Honeywell S8610M Continous Retry Crown Boiler Circuit Board. 5.0 out of 5 stars 1 product rating. 5.0 average based on 1 product rating. 5. 1 users rated this 5 out of 5 stars 1. 4. …Get Price

  • Burnham Series 2 Boiler Manual - hoteldesetuves.fr

    · I have a burnham series 2( model B) gas boiler model number In the burnham manual it lists 2 one is a honeywell L4080D1036 and the other one the manual li read more. Parts4Heatingcom 100333-01 Gas Valve - 40mm Only Continuous Ignition Standing Pilot Nat Gas Only High Altitude Only 2000-5000 ft VR8200C6032. Get a Quote.Get Price

  • Burnham | K50 | User manual | Burnham K50 User's Manual

    View online (116 pages) or download PDF (4 MB) Burnham K50 User manual • K50 water heaters & boilers PDF manual download and more Burnham online manualsGet Price

  • 71-97406 Controls for Oil-Fired Heating - Honeywell

    Boilers, warm-air furnaces, and heating appliances. Return-flow pressure or modulating pressure 3500 and greater 25 and greater No. 2 and heavier Boilers and warm-air furnaces. Air 70 to 1000 0.5 to 70 No. 2 and heavier Boilers and warm-air furnaces. Horizontal rotary cup. 750 to 37,000 5 to 300 No. 2 for smaller capacities and no. 4,Get Price

  • Burnham 5B Brochure | Manualzz

    Series 5B COMMERCIAL ATMOSPHERIC GAS-FIRED STEAM BOILER 401 TO 1950 MBH INPUT CAST IRON SECTIONAL DESIGN 15 PSI STEAM ONLY ATMOSPHERIC VENT SUITED TO LOW CEILING HEIGHT 77% THERMAL EFFICIENCY Series 5B STEAM BOILER Quality You Can Count On The Burnham Commercial Series 5B boiler offers heating capacities and features that make it …Get Price

  • burnham boiler wiring diagram - bleuwinginvestigations.com

    Honeywell Wifi Thermostat With Burnham Gas Furnace Doityourself Com Community Forums. The Burnham Commercial V9A boiler is ideal for use in commercial installations because it is versatile enough to meet specific job requirements. The Series 2 boilers are low pressure cast iron gas fired hot water boilers. This relatively small device is responsible for controlling the …Get Price

  • S8610M3009 - Honeywell S8610M3009 - One-Rod Intermittent

    Honeywell S8610M3009 - One-Rod Intermittent Pilot Control - Note: Image may not be an exact representation of the item. The item will either have a black or white plastic cover. Overview Provide electronic control of intermittent pilot ignition systems used on gas-fired furnaces, boilers and other heating appliances.Get Price

  • I have a Burnham boiler with a honeywell s8610m continuous

    Nov 30, 2016 · I have a Burnham boilerwith a honeywell s8610m continuous retry controller. It ignites fine, burns for between 5 and 25 seconds, and then cycles off. Then goes through the ignition process again. This happens somewhat sporadically, but always at the most inconvenient times. I'm not sure I'm reading the light status codes correctly.Get Price

  • S8610M Honeywell Ignition Control / Continuous

    S8610M Honeywell Ignition Control / Continuous RetryHoneywell Ignition Control / | partsforboilers.Get Price

  • burnham boiler and field controls — Heating Help: The Wall

    Burnham boilers and Field Controls I just converted a Burnham standing pilot gas boiler to electronic ignition. Iam trying to wire in a Field Controls CAS4 and PV300 power venter i cannot figure out the low voltage wiring the latest Field Controls wiring book does not show the Honeywell smart valve i have called tech support and local reps to no avail has anyone done a …Get Price

  • Amazon.com: Honeywell International S8610U3009 Module

    My boiler had an S8610M module and was acting strange. The pilot would light immediately but it would keep sparking for an extra few seconds, then the main burners would come on for a few minutes but shut off for no reason. It would then "retry" igniting the pilot, even though the pilot was on.Get Price

  • Aquastat settings: Best High, Low, & DIFF Settings on a

    Guide to Best Settings for the HI Limit on a Honeywell R8182D Heating Boiler Aquastat & Similar Controls: The "HI" on a combination heating control like this aquastat is usually set by the heating service technician to a spot between 180 °F and 200 °F. Or the "rule of thumb" fellows just park it at about "180" °F as you can see in our photo.Get Price

  • Burnham gas furnace troubleshooting" Keyword Found

    Burnham Boiler Reviews 2021 Quality Efficiency Ratings. Highperformancehvac.com DA: 23 PA: 41 MOZ Rank: 100. Most Burnham boilers are gas-fired, but Burnham does have oiled-fired boilers; While the fuel changes from gas to oil, the efficiency rating is decent for the oil boilerGet Price

  • SERIES 8H ATMOSPHERIC: GAS FIRED HOT WATER BOILER

    Aug 08, 2019 · firing up to eight boiler modules. It shall have fixed reset ratio of 1.5:1, 1:1, or 1:1.5. It shall consist of a T475A control with 30ft. capillary on first boiler and (1) T6031A outdoor air sensor with 20 ft. capillary and bulb shield on each additional boiler. Provide a Burnham Control Package B. Option (d)Get Price

  • Honeywell S8600m Troubleshooting [YRQOAE]

    Jun 07, 2021 · It is equipped with a Honeywell S8600M continuous retry 100 Answered by a verified HVAC Technician' 'UTICA GAS BOILER SERVICE MANUAL URBANLOVEWARRIOR COM APRIL 21ST, 2018 - UTICA GAS BOILER INSTALLATION MANUAL PDF EBOOK DOWNLOAD THE BOILER IS A UTICA MGB100HID GAS BOILER IS A UTICA GAS MODEL PGB175''Boilers Gas …Get Price

Discount
7X24 Online