Press the left button, drag the mouse, rotate the cube, see more information

Limit Discounts

Through this webpage, choose online customer service communication, or message board. Leave your needs and get limited time discounts, up to 10% off, saving you a fortune. This discount has an indefinite period, and places are limited on a first-come, first-served basis.

Payment Method

We support various payment methods:
T/T payment
VISA
paypal
MasterCard
Alipay etc
Save time in your buying process.

Certified Product

The company's products have passed multiple national
certifications:
for example:
United States: ASME
EU: CE
Eastern Europe: EAC
Russia: GOST
Singapore: MOMO
etc
Buy products, buy with confidence, use with confidence

Product Type

Domestic hot water and heating series: gas hot water boiler, vacuum hot water boiler, vertical atmospheric pressure hot water boiler, electric hot water boiler Factory use, high temperature steam: wns fuel gas steam boiler, szs water tube steam boiler, vertical steam boiler, electric steam boiler

About Us

FANGKUAI is founded in 1998, which is a clean fuel boiler enterprise integrating R&D, manufacturing, sales and service. In the past 20 years of development and innovation, the company has grown into a global enterprise, and its products have been exported to more than 80 countries including Russia, Mongolia and Thailand, and have established long-lasting cooperative relations with local enterprises!

Contact Us

If you are interested in our company or products, you can contact with us through online consulting, demand table submission, e-mails and telephones. Our staff shall wholeheartedly provide product information, application knowledge and good service for you.

chloride limit in boiler drum

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :chloride limit in boiler drum
  • Supply Capacity : 10 units/month :chloride limit in boiler drum
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

boilermanufactory

Get display discount

boiler
Contact us

Global Sales Hotline:
0086-371-60922096

Email: [email protected]

Voicemail
  • Boiler Water Tests | Viking Water Technology, Inc.

    May 04, 2016 · Boiler pH should be kept between 10.5 and 12.5. Below 10.5, there is insufficient protection from corrosion and hardness compounds are not precipitated in the desired, free-flowing form. Above 12.5 there is the possibility of caustic embrittlement and carryover. Condensate pH should be kept between 8.0 and 8.6.Get Price

  • How to Destroy a Boiler -- Part 1

    Adjust continuous blowdown to maintain the conductivity of the boiler water within acceptable limits and blow down the mud drum on a regular basis. It is also important to blow the sludge out of all the dead legs of the low-water trips, water column, etc., on a regular basis to prevent sludge buildup in these areas.Get Price

  • What is the effect of chloride in boiler? - Answers

    Jun 17, 2012 · it acts as a cleaning agent. chloride isn't a thing on its own and the melting and boiling points of chlorine and magnesium will have no effect on the boiling and melting point og magnesium chloride.Get Price

  • RECOMMENDED WATER/STEAM CHEMISTRY LIMITS FOR HRSG

    The chemical limits are always dictated by the steam purity requirements, the highest drum pressure on the HRSG, and, if applicable, by the highest pressure at the duct-fired condition. The term "drum water" is equivalent to "boiler water" for the purposes of this document. Chloride as Cl, ppm (mg/l) 50. Silica as SiO 2, ppm (mg/l) 25.Get Price

  • Boiler Water Treatment - An overview - Marinerspoint

    Apr 29, 2020 · Answer: The water enters the boiler from the cascade tank will evaporate .Produced steam is very fine and will contain so chloride as it is heavier .So the chloride will remain in the water drum. As more feed water will enter the boiler the chlorides will be added .This process is continuous and if the chlorine id not blown down regularly it Get Price

  • Boiler Water Conductivity Measurement Fundamentals

    Feb 24, 2016 · For boiler water, the conductivity increases at the rate of approximately 2% (of the value at 25°C) for every 1°C increase in temperature. This can be written as: σ T = σ25 [1 + α (T – 25)] σT = Conductivity at temperature T (µS / cm) α = Temperature coefficient, per °C (Typically 0.02 / °C or 2%°C)Get Price

  • IS 10496 (1983): Feed Water, Boiler Water and Condensate

    Jan 07, 1983 · 2.1 Water-Tube Boilers ( Drum Type) - The feed water, boiler water and condensate, for water-tube boilers shall cotiply with the requirements given in Table 1. NOTE -In case of recovery boilers operating at low boiler pressures of I.5 to 2.0Get Price

  • Chloride content guidelines in the water of a 2100 psi

    What maximum chloride levels (in PPM) should be maintained in boiler Get Price

  • Chlorides & Steam — Heating Help: The Wall

    Apr 01, 2006 · Testing of boiler water for large steam boilers needs to become a routine to MAINTAIN chloride levels below 100ppm. Bottom blowdowns are a necessary evil where boiler water treatment is concerned. Welding is a costly alternative. You may have to some frequent bottom blowdowns and test to lower the chlorides, then start testing daily and keep a Get Price

  • Chloride content guidelines in the water of a 2100 psi

    Jan 07, 2016 · I'm trying to look for limits and guidelines about chloride content in the water for high pressure coal fired boiler (meassured in make-up water and boiler drum). I have foung some information but it's so dispersive, I've seen limits from 12 …Get Price

  • Boiler Water - Problems & Solutions

    Boiler Water - Problems & Solutions Website:-.rxmarine.com 105 A-Wing BSEL Tech Park Opp. Vashi Railway Station, Navi Mumbai pin- 400703 Contact:-022-65119999-5555-3333Get Price

  • Controlling TDS in the Boiler Water | Spirax Sarco

    An increase in temperature results in an increase in electrical conductivity. For boiler water, the conductivity increases at the rate of approximately 2% (of the value at 25°C) for every 1°C increase in temperature. This can be written as: Example 3.12.3. A boiler water sample has an unneutralised conductivity of 5 000 μS/cm at 25°C.Get Price

  • Feed Water - Chemistry Limits

    Related Topics . Steam and Condensate - Steam & condensate systems- properties, capacities, pipe sizing, systems configuration and more; Related Documents . ASME - International Boiler and Pressure Vessel Code - The International Boiler and Pressure Vessel Code safety rules governing design, fabrication, and inspection of boilers and pressure vessels, and nuclear power plant …Get Price

  • What is Boiler Mountings?- Complete List With Functions

    A vent valve is installed on the boiler shell to vent air from the steam drum during starting of the boiler. These vent valves also come in handy during boiler shutdown as they let fresh air enter the boiler drum avoiding its collapse under pressure. A vent valve can also be used to release/dump moist steam at the start. 4. Pressure GaugeGet Price

  • Boiler Water / Feedwater Flashcards | Quizlet

    What is defined as the feedwater that enters the boiler steam drum? Boiler water. PH of 7 is defined as? Neutral. What will increase in boiler water due to an excess of hydrogen? Acidity. What is the maximum chloride limit on ALL naval boilers? 1.00 EPM.Get Price

  • STEAM GENERATION IN POWER PLANTS - Hach Company

    Steam generation (drum boilers) Water treatment plant The purity of make-up water is critical in maintaining steam quality and in limiting boiler blowdown. Raw water pre-treatment Raw water contains organic matter, inorganic salts, bacteria which need to be removed before being purified.Get Price

  • CHAPTER 17 Boiler Water chemistry and Chemical Treatment

    Presence of chloride in feed water is harmful to the system as whole. Hence it is very advisable to limit chloride concentration in feed water, keeping in mind, limit prescribed for boiler water and restriction as per drum pressure ratings. Leak proof condenser and …Get Price

  • Boiler Water Treatment

    2/18/2014 3 Cheat Sheet - Reactions • Bicarbonate Break: Na 2 HCO 3 + HEAT Na 2 CO 3 + CO 2 + H 2 O • Developed Alkalinity: Na 2 CO 3 + HEAT + 2H 2 O 2NaOH + CO 2 + H 2 O • Brining Reactions: CaCl + Boiler Water CaSO 4 + CaSiO 3 • Phosphate Reactions: …Get Price

  • STEAM PURITY STRESS CORROSION CRACKING

    tation for drum boilers should be used to For drum type units operated with the provide assurance against the type of coordinated phosphate boiler water treat- chemical upsets described above. ment, it is not evident what levels of sodium and cation conductivity are achiev- Saturated steam sampling at the drum mayGet Price

  • (PDF) BASIC WATER TREATMENT OF STEAM BOILERS | …

    As the boiler is filled, the drum collects the overflow. Then, as a vacuum develops because of cooling, the water in the drum enters the boiler and keeps it full. Additional water added to keep the drum filled should be treated with sulfite (1 oz per 50 gallons) and caustic (approximately 1.5 oz per 50 gallons). 7.Get Price

  • (PDF) Chloride Contamination of the Water/Steam Cycle in

    Unit load versus chloride and sulphate concentrations in the boiler drum for periods preceding (January 1 to January 13, 2011) and during (January 14 to April 8, 2011) the low level (LL) tank Get Price

  • Sodium Monitoring TECHNICAL NOTE On Power Plant

    chloride measurement techniques. 5 – Polishing Plant Outlet The polishing plant is used mainly on Once Through type boilers to reduce chemical contamination, which is far more critical on this type of boiler. Because a polishing plant is similar to a water treatment plant, sodium monitors can be used again to detect resin exhaustion and monitorGet Price

  • Boiler water chemistry - Properties of feed water explored

    Jul 16, 2009 · The more the chloride ions, the more the scale formation. Therefore,it is necessary to limit it as low as possible. The problem with chloride ions is that high degree of dissolution makes it difficult to remove them at a later stage. It also serves as a standard of boiler water concentration together with total solids.Get Price

  • Chloride content guidelines in the water of a 2100 psi

    Mar 11, 2019 · WATER TREATMENT. … 14 2800 Sufficient product for high speed engines using water that contains up to 50ppm Chloride. Boiler feedwater – Wikipedia Boiler feedwater is an essential part of boiler operations. The feed water is put into the steam drum from a feed pump. In the steam drum the feed water is then ….Get Price

  • Water, steam, and turbine deposit chemistries in phosphate

    Only drum boiler units using phosphate boiler water treatment are included in this study. Information on concentration and transport of chemical impurities and sodium phosphate around drum boiler cycles was collected and correlated with chemical composition of low pressure (LP) turbine deposits collected after the water and steam sampling.Get Price

  • BASIC WATER TREATMENT OF STEAM BOILERS

    May 02, 2000 · ASME Guidelines for Water Tube Boilers Drum Pressure Iron Copper Total Silica Total Conductivity surpasses its solubility limit, it begins to form deposits or precipitate. The actual limits are so the boiler chloride concentration must never exceed 100ppm.Get Price

  • MM2 Northstar Boilers and Fittings Flashcards | Quizlet

    When steam drum pressure is 100 too 200 psi below the lowest safety valve setting or 75 percent or working pressure, whichever is higher. What is the maximum chloride limit on all naval boilers? 1.00 equivalent per million (EPM) What type of deposits act as insulators and reduces the heat transfer across any surface ?Get Price

  • Boiler Water Treatment

    2/18/2014 3 Cheat Sheet - Reactions • Bicarbonate Break: Na 2 HCO 3 + HEAT Na 2 CO 3 + CO 2 + H 2 O • Developed Alkalinity: Na 2 CO 3 + HEAT + 2H 2 O 2NaOH + CO 2 + H 2 O • Brining Reactions: CaCl + Boiler Water CaSO 4 + CaSiO 3 • Phosphate Reactions: …Get Price

  • Steam Purity - boiler-wrba.org

    •Operating variables such as high steam load above boiler design •Steam space in the Drum level being minimal for good EPRI limits for Boiler, Feedwater and Steam . Turbine Steam Purity Specifications hydroxide and sodium chloride are major corrodents of the turbine blading.Get Price

  • What maximum chloride levels (in PPM) should be …

    What maximum chloride levels (in PPM) should be maintained in boiler Get Price

Discount
7X24 Online